TABLE TOP FRONT LOADING AUTOCLAVE 17 LTR CLASS B

Model No : AUTT 401

Type : Table Top Autoclave

Specification :

These Autoclaves are used in Ophthalmic, Dental , R & D Centres and Micro Biology Laboratory

Pre Vacuum : Autoclave Class B is designed to get efficient Pre Vacuum condition in order to result to achieve better sterilization result.

Post Vacuum : Autoclave Class B post vacuum is designed in such a way to get better drying

Air Leakage Test : Autoclave Class B has inbuilt program to confirm air leakage rate is as per the requirement of EN 13060:2004

Bowie - Dick Test : Autoclave Class B has inbuilt program for Bowie - Dick Test packs to determine performance efficiency as per requirement of EN 13060:2004

Process Challenge Device Test : Autoclave Class B also passed Process Challenge Device Test for hollow loads according to requirement of EN 13060:2004

Recorder Printer : Autoclave Class B can print out all parameters viz. sterilization pressure, sterilization temperature, sterilization time and dry time etc with year / month / day / hour / Error Messages / Cycle time, various phases etc.

Mode Selections are as below:

* Package programs to sterilize packed articles sterilization temperature : 134°C,

sterilization time : 4 minutes & dry time : 15 minutes. 

* Instrument programs to sterilize metallic devices sterilization temperature : 134°C, sterilization time : 4 minutes & dry time : 15 minutes.

* Rubber programs to sterilize rubber & plastic sterilization temperature : 121°C, 

sterilization time : 20 minutes & dry time : 15 minutes.

* Liquid programs to sterilize liquid sterilization temperature : 121°C, 

sterilization time : 20 minutes & dry time : 15 minutes.

Manual Program can be set as per user requirements. Program can be set for pre vacuum, post vacuum sterilization temperature : 121°C~134°C, sterilization time : 1~60 minutes, dry time : 1~60 minutes.

Chamber is Cylinderical and Size is 225mm Dia x 430mm Depth

The capacity of the Chamber is 17 Ltr

Reservoir Capacity is 3 Litre

There are 3 No Loading Tray Size 150mmx380mmx14mm

Power is 220V 50/60Hz, 15A

Power Consumption is 1800 W

Temperature Range is 121°C (1.1bar)-134°C (2.1bar)

Autoclave has Digital Pressure Display 

There is printer provided with the Autoclave 

Dry System  Vacuum Heat Drying

Control System is Automatic Micro Processor Based

Display of Table Top Front Loading Autoclave is LED .

Model No     Size in inch       Size in mm     Capacity (Ltr)

AUTT 401      9 x 18 Inch      225 x 430 mm         17 Ltr